Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Mais filtros











Intervalo de ano de publicação
2.
Anal Bioanal Chem ; 414(5): 1949-1962, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34981149

RESUMO

Recently, numerous diagnostic approaches from different disciplines have been developed for SARS-CoV-2 diagnosis to monitor and control the COVID-19 pandemic. These include MS-based assays, which provide analytical information on viral proteins. However, their sensitivity is limited, estimated to be 5 × 104 PFU/ml in clinical samples. Here, we present a reliable, specific, and rapid method for the identification of SARS-CoV-2 from nasopharyngeal (NP) specimens, which combines virus capture followed by LC-MS/MS(MRM) analysis of unique peptide markers. The capture of SARS-CoV-2 from the challenging matrix, prior to its tryptic digestion, was accomplished by magnetic beads coated with polyclonal IgG-α-SARS-CoV-2 antibodies, enabling sample concentration while significantly reducing background noise interrupting with LC-MS analysis. A sensitive and specific LC-MS/MS(MRM) analysis method was developed for the identification of selected tryptic peptide markers. The combined assay, which resulted in S/N ratio enhancement, achieved an improved sensitivity of more than 10-fold compared with previously described MS methods. The assay was validated in 29 naive NP specimens, 19 samples were spiked with SARS-CoV-2 and 10 were used as negative controls. Finally, the assay was successfully applied to clinical NP samples (n = 26) pre-determined as either positive or negative by RT-qPCR. This work describes for the first time a combined approach for immuno-magnetic viral isolation coupled with MS analysis. This method is highly reliable, specific, and sensitive; thus, it may potentially serve as a complementary assay to RT-qPCR, the gold standard test. This methodology can be applied to other viruses as well.


Assuntos
Teste para COVID-19/métodos , COVID-19/diagnóstico , Cromatografia Líquida/métodos , Separação Imunomagnética/métodos , SARS-CoV-2/genética , Espectrometria de Massas em Tandem/métodos , Sequência de Aminoácidos , Anticorpos Antivirais/química , Biomarcadores/química , COVID-19/imunologia , COVID-19/virologia , Teste para COVID-19/instrumentação , Teste para COVID-19/normas , Cromatografia Líquida/instrumentação , Cromatografia Líquida/normas , Humanos , Separação Imunomagnética/instrumentação , Separação Imunomagnética/normas , Nasofaringe/virologia , Peptídeos/química , Peptídeos/imunologia , SARS-CoV-2/imunologia , Sensibilidade e Especificidade , Espectrometria de Massas em Tandem/instrumentação , Espectrometria de Massas em Tandem/normas
5.
Mikrochim Acta ; 188(10): 335, 2021 Sep 09.
Artigo em Inglês | MEDLINE | ID: mdl-34505191

RESUMO

A practical colorimetric assay was developed for the detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). For this purpose, magnetic γ Fe2O3 nanoparticles were synthesized and used as a peroxidase-like mimic activity molecule. In the presence of γ Fe2O3 nanoparticles, the color change of H2O2 included 3,3',5,5'-tetramethylbenzidine was monitored at the wavelength of 654 nm when spike protein interacted with angiotensin-converting enzyme 2 receptor. This oxidation-reduction reaction was examined both spectroscopically and by using electrochemical techniques. The experimental parameters were optimized and the analytical characteristics investigated. The developed assay was applied to real SARS-CoV-2 samples, and very good results that were in accordance with the real time polymerase chain reaction were obtained.


Assuntos
Teste para COVID-19/métodos , COVID-19/diagnóstico , Colorimetria/métodos , Nanopartículas Magnéticas de Óxido de Ferro/química , SARS-CoV-2/química , Glicoproteína da Espícula de Coronavírus/química , Enzima de Conversão de Angiotensina 2/metabolismo , Benzidinas/química , Técnicas Biossensoriais/métodos , Teste para COVID-19/instrumentação , Catálise , Compostos Cromogênicos/química , Cisteína/química , Humanos , Peróxido de Hidrogênio/química , Limite de Detecção , Nasofaringe/virologia , Orofaringe/virologia , Oxirredução , Peroxidase/química , Glicoproteína da Espícula de Coronavírus/metabolismo
6.
Acc Chem Res ; 54(19): 3643-3655, 2021 10 05.
Artigo em Inglês | MEDLINE | ID: mdl-34516092

RESUMO

Reliable, inexpensive, and rapid diagnostic tools are essential to control and prevent the spread of infectious diseases. Many commercial kits for coronavirus disease 2019 (COVID-19) diagnostics have played a crucial role in the fight against the COVID-19 pandemic. Most current standard in vitro diagnostic (IVD) protocols for infectious diseases are sensitive but time-consuming and require sophisticated laboratory equipment and specially trained personnel. Recent advances in biosensor technology suggest the potential to deliver point-of-care (POC) diagnostics that are affordable and provide accurate results in a short time. The ideal "sample-in-answer-out" type fully integrated POC infection diagnostic platforms are expected to be autonomous or easy-to-operate, equipment-free or infrastructure-independent, and high-throughput or easy to upscale. In this Account, we detail the recent progress made by our group and others in the development of centrifugal microfluidic devices or lab-on-a-disc (LOAD) systems. Unlike conventional pump-based fluid actuation, the centrifugal force generated by spinning the disc induces liquid pumping and no external fluidic interconnects are required. This allows a total fluidic network required for multiple steps of biological assays to be integrated on a disc, enabling fully automated POC diagnostics. Various applications have been demonstrated, including liquid biopsy for personalized cancer management, food applications, and environmental monitoring; here, we focus on IVD for infectious disease. First, we introduce various on-disc unit operation technologies, including reagent storage, sedimentation, filtration, valving, decanting, aliquoting, mixing, separation, serial dilution, washing, and calibration. Such centrifugal microfluidic technologies have already proved promising for micro-total-analysis systems for automated IVD ranging from molecular detection of pathogens to multiplexed enzyme-linked immunosorbent assays (ELISAs) that use raw samples such as whole blood or saliva. Some recent examples of LOAD systems for molecular diagnostics in which some or all steps of the assays are integrated on a disc, including pathogen enrichment, nucleic acid extraction, amplification, and detection, are discussed in detail. We then introduce fully automated ELISA systems with enhanced sensitivity. Furthermore, we demonstrate a toy-inspired fidget spinner that enables electricity-free and rapid analysis of pathogens from undiluted urine samples of patients with urinary tract infection symptoms and a phenotypic antimicrobial susceptibility test for an extreme POC diagnostics application. Considering the urgent need for cost-effective and reliable POC infection diagnostic tools, especially in the current pandemic crisis, the current limitations and future directions of fast and broad adaptation in real-world settings are also discussed. With proper attention to key challenges and leverage with recent advances in bio-sensing technologies, molecular biology, nanomaterials, analytical chemistry, miniaturization, system integration, and data management, LOAD systems hold the potential to deliver POC infection diagnostic tools with unprecedented performance regarding time, accuracy, and cost. We hope the new insight and promise of LOAD systems for POC infection diagnostics presented in this Account can spark new ideas and inspire further research and development to create better healthcare systems for current and future pandemics.


Assuntos
Teste para COVID-19/métodos , COVID-19/diagnóstico , Sistemas Automatizados de Assistência Junto ao Leito , Técnicas Biossensoriais/métodos , COVID-19/virologia , Teste para COVID-19/instrumentação , Centrifugação , Humanos , Dispositivos Lab-On-A-Chip , RNA Viral/análise , RNA Viral/isolamento & purificação , RNA Viral/metabolismo , SARS-CoV-2/genética , SARS-CoV-2/isolamento & purificação
7.
PLoS One ; 16(9): e0256877, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34473769

RESUMO

In French Polynesia, the first case of SARS-CoV-2 infection was detected on March 10th, 2020, in a resident returning from France. Between March 28th and July 14th, international air traffic was interrupted and local transmission of SARS-CoV-2 was brought under control, with only 62 cases recorded. The main challenge for reopening the air border without requiring travelers to quarantine on arrival was to limit the risk of re-introducing SARS-CoV-2. Specific measures were implemented, including the obligation for all travelers to have a negative RT-PCR test for SARS-CoV-2 carried out within 3 days before departure, and to perform another RT-PCR testing 4 days after arrival. Because of limitation in available medical staff, travelers were provided a kit allowing self-collection of oral and nasal swabs. In addition to increase our testing capacity, self-collected samples from up to 10 travelers were pooled before RNA extraction and RT-PCR testing. When a pool tested positive, RNA extraction and RT-PCR were performed on each individual sample. We report here the results of COVID-19 surveillance (COV-CHECK PORINETIA) conducted between July 15th, 2020, and February 15th, 2021, in travelers using self-collection and pooling approaches. We tested 5,982 pools comprising 59,490 individual samples, and detected 273 (0.46%) travelers positive for SARS-CoV-2. A mean difference of 1.17 Ct (CI 95% 0.93-1.41) was found between positive individual samples and pools (N = 50), probably related to the volume of samples used for RNA extraction (200 µL versus 50 µL, respectively). Retrospective testing of positive samples self-collected from October 20th, 2020, using variants-specific amplification kit and spike gene sequencing, found at least 6 residents infected by the Alpha variant. Self-collection and pooling approaches allowed large-scale screening for SARS-CoV-2 using less human, material and financial resources. Moreover, this strategy allowed detecting the introduction of SARS-CoV-2 variants of concern in French Polynesia.


Assuntos
Teste para COVID-19/métodos , COVID-19/diagnóstico , Programas de Rastreamento/métodos , Vigilância da População/métodos , Manejo de Espécimes/métodos , Viagem , COVID-19/epidemiologia , COVID-19/virologia , Teste para COVID-19/instrumentação , Epidemias/prevenção & controle , França/epidemiologia , Humanos , Polinésia/epidemiologia , Estudos Prospectivos , RNA Viral/genética , RNA Viral/isolamento & purificação , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , SARS-CoV-2/genética , SARS-CoV-2/fisiologia , Manejo de Espécimes/instrumentação
8.
J Clin Lab Anal ; 35(9): e23888, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34213803

RESUMO

BACKGROUND: The Hologic Aptima™ TMA SARS-CoV-2 assay was employed to test pooled nasopharyngeal (NP) samples to evaluate the performance of pooled sample testing and characterize variables influencing results. METHODS: Results on 1033 previously tested NP samples were retrieved to characterize the relative light units (RLU) of SARS-CoV-2-positive samples in the tested population. The pooling strategy of combining 10 SARS-CoV-2 samples into one pool (10/1) was used in this study. The results were compared with neat sample testing using the same Aptima™ TMA SARS-CoV-2 assay and also the CDC RT-PCR and the Cepheid SARS-CoV-2 assays. RESULTS: The Aptima assay compares favorably with both CDC RT-PCR and the Cepheid SARS-CoV-2 assays. Once samples are pooled 10 to 1 as in our experiments, the resulting signal strength of the assay suffers. A divide opens between pools assembled from strong-positive versus only weak-positive samples. Pools of the former can be reliably detected with positive percent agreement (PPA) of 95.2%, while pools of the latter are frequently misclassified as negative with PPA of 40%. When the weak-positive samples with kRLU value lower than 1012 constitute 3.4% of the total sample profile, the assay PPA approaches 93.4% suggesting that 10/1 pooled sample testing by the Aptima assay is an effective screening tool for SARS-CoV-2. CONCLUSION: Performing pooled testing, one should monitor the weak positives with kRLU lower than 1012 or quantification cycle (Cq) value higher than 35 on an ongoing basis and adjust pooling approaches to avoid reporting false negatives.


Assuntos
Teste para COVID-19/métodos , COVID-19/diagnóstico , Nasofaringe/virologia , SARS-CoV-2/isolamento & purificação , COVID-19/virologia , Teste para COVID-19/instrumentação , Reações Falso-Negativas , Humanos , Programas de Rastreamento/métodos , Reprodutibilidade dos Testes , Reação em Cadeia da Polimerase Via Transcriptase Reversa , SARS-CoV-2/genética
10.
Acad Med ; 96(7): 954-957, 2021 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-33496428

RESUMO

Machine learning (ML) algorithms are powerful prediction tools with immense potential in the clinical setting. There are a number of existing clinical tools that use ML, and many more are in development. Physicians are important stakeholders in the health care system, but most are not equipped to make informed decisions regarding deployment and application of ML technologies in patient care. It is of paramount importance that ML concepts are integrated into medical curricula to position physicians to become informed consumers of the emerging tools employing ML. This paradigm shift is similar to the evidence-based medicine (EBM) movement of the 1990s. At that time, EBM was a novel concept; now, EBM is considered an essential component of medical curricula and critical to the provision of high-quality patient care. ML has the potential to have a similar, if not greater, impact on the practice of medicine. As this technology continues its inexorable march forward, educators must continue to evaluate medical curricula to ensure that physicians are trained to be informed stakeholders in the health care of tomorrow.


Assuntos
Atenção à Saúde/organização & administração , Educação Médica/métodos , Medicina Baseada em Evidências/história , Aprendizado de Máquina/estatística & dados numéricos , Idoso , Algoritmos , Teste para COVID-19/instrumentação , Tomada de Decisão Clínica/ética , Ensaios Clínicos como Assunto , Currículo/estatística & dados numéricos , Atenção à Saúde/estatística & dados numéricos , Retinopatia Diabética/diagnóstico , Diagnóstico por Imagem/instrumentação , Feminino , História do Século XX , Humanos , Responsabilidade Legal , Masculino , Relações Médico-Paciente/ética , Médicos/organização & administração , Participação dos Interessados , Estados Unidos , United States Food and Drug Administration/legislação & jurisprudência
12.
Clin J Gastroenterol ; 14(1): 44-47, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32951147

RESUMO

Long and sharp objects can be foreign body intentionally or accidentally ingested. Timing of endoscopy relies on foreign body shape and size, localization in gastrointestinal tract, patient's clinical conditions, occurrence of symptoms, or onset of complications. We present a case of a 47-year-old male with no known comorbidity, who accidentally swallowed a portion of a naso-pharyngeal swab half-broken during the second diagnostic test for SARS-CoV-2. The intact swab had a total length of 15 cm and was made of wood. The patient was asymptomatic, laboratory tests were normal, and neck-chest-abdominal X-ray and CT scan were negative for major complications. Upper gastrointestinal endoscopy was promptly performed to prevent the long sharp swab from crossing the pylorus leading to serious complications and, therefore, risk surgical intervention. The patient was intubated and the procedure was carried out under general anesthesia. In the gastric body, broken naso-pharyngeal swab was detected among the food debris, and using a latex rubber hood, the 7.5 cm foreign body was removed with a retrieval alligator-tooth forceps. Our hospital is located in a high-risk area of COVID-19 outbreak where many naso-pharyngeal swabs are performed, and to our knowledge, this is the first report of swab ingestion during SARS-CoV-2 test.


Assuntos
Teste para COVID-19 , COVID-19 , Corpos Estranhos , Gastroscopia/métodos , Manejo de Espécimes , COVID-19/diagnóstico , COVID-19/epidemiologia , COVID-19/prevenção & controle , Teste para COVID-19/instrumentação , Teste para COVID-19/métodos , Deglutição , Equipamentos para Diagnóstico/efeitos adversos , Corpos Estranhos/diagnóstico por imagem , Corpos Estranhos/etiologia , Corpos Estranhos/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , SARS-CoV-2/isolamento & purificação , Manejo de Espécimes/efeitos adversos , Manejo de Espécimes/instrumentação , Manejo de Espécimes/métodos , Resultado do Tratamento
13.
Braz. arch. biol. technol ; 64(spe): e21200147, 2021. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1285565

RESUMO

Abstract With the COVID-19 pandemic, many diagnostic tests (molecular or immunological) were rapidly standardised, given the urgency of the situation, many are still in the process of being validated. The main objective of this study was to review the aspects of the diagnostic kits approved in Brazil and their application in the different federative units to gather epidemiological information. In order to achieve these objectives, a survey was carried out on the data available at the regulatory agency (ANVISA) and in the literature. The main countries that have registered products in Brazil are China (51.4%), Brazil (16.6%), South Korea (9.2%), USA (8.8%) and Germany (3.6%). The methodologies of these products are based on the detection of nucleic-acid (15.8%), antigen (13%) and antibody (71.2%). In the immunological tests, it was verified that the sensitivity ranged from 55 to 100% and the specificity from 80 to 100%. The percentage of cases in the samples tested in Brazil is elevated in almost all federative units since eight states showed 40% of positive cases in tested samples, while 18 states displayed between 20 and 40%. In conclusion, this review showed that Brazil is dependent on external technology to respond to pandemics, epidemics and endemics disease and needs to improve its biotechnological scheme to solve further diseases outbreaks.


Assuntos
Humanos , Coronavírus Relacionado à Síndrome Respiratória Aguda Grave/isolamento & purificação , COVID-19/diagnóstico , Testes Imunológicos/instrumentação , Brasil/epidemiologia , Ensaio de Imunoadsorção Enzimática/instrumentação , Cromatografia de Afinidade/instrumentação , Teste para COVID-19/instrumentação , Teste de Ácido Nucleico para COVID-19/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA